Conventional Double Plug Cement Head
Built for standard cementing jobs, this head holds and releases two plugs (bottom and top) on casing sizes from 2 7/8″ to 20″. It’s a reliable, cost-effective choice for typical surface pressures.
Size & Working Pressure
| Casing Size Range | Working Pressure (PSI) |
|---|---|
| 2 7/8″ – 9 5/8″ | 5,000 |
| 10 3/4″ – 13 3/8″ | 3,000 |
| 16″ – 20″ | 1,500 |
Extra High Pressure Double Plug Cement Head
Engineered for tougher wells, this head handles higher surface pressures while launching two plugs, covering sizes from 2 7/8″ to 20″. Choose it when you expect elevated treating or bump pressures.
Size & Working Pressure
| Casing Size Range | Working Pressure (PSI) |
|---|---|
| 2 7/8″ – 7″ | 10,000 |
| 7 5/8″ – 9 5/8″ | 7,500 |
| 10 3/4″ – 13 3/8″ | 5,000 |
| 16″ – 20″ | 3,000 |
Use the Conventional head for routine jobs and typical pressures; step up to the Extra High Pressure head when your expected surface pressure plus safety margin exceeds the conventional rating for that size.
Contact us with your casing size and expected surface pressure; we’ll help you choose the right double plug cement head and share pricing and lead time.